Back

Questions Every Embryologist Should Ask Before Buying a Time lapse Incubator

Critical Questions Every Embryologist Should Ask Before Getting a Timelapse Incubator
  • Share

Consider the last time you bought a smart phone. You probably looked at its camera quality, storage space, battery life, processor and overall performance before you decided. Maybe you’ve read the reviews, looked at the different models, and compared features and price. We know what we’re looking for and which specs matter to us, even on everyday purchases.

But what happens when the purchase is a time-lapse incubator for an IVF laboratory?

With multiple systems available, each offering different technologies, choosing the right time-lapse incubator can be far more complex than comparing prices or looking at product brochures.

Do we know exactly which specifications to compare? Which questions should we ask during a product demonstration? And how do we evaluate features that affect day to day lab workflow, usability and longer term equipment management?

A time-lapse incubator is a huge investment, hence it’s important to understand how and what are the differences between systems, and what points to analyze before purchasing. The points of consideration are way more detailed than just the initial cost of the unit. The embryologists may not always have known the right questions to ask in order to evaluate the technical and operational differences between various incubator systems available in the market.

At Hanahealth by DSS, we believe the first step of purchasing should be understanding what to look for. In this guide, we will outline essential questions embryologists should be asking when reviewing time-lapse incubators. This includes chamber and imaging design, imaging criteria and resolution, software and hardware features, service and support, and overall reliability of a given time lapse incubator. Our goal is to provide the tools and knowledge to help embryologists look beyond price when selecting a time-lapse incubator for their laboratory.

A Few Critical Questions Every Embryologist Should Ask Before Buying a Time-Lapse Incubator:-

1. Does Each Patient Have a Dedicated Incubation Chamber?

Chamber design is one of the first specifications to consider when reviewing time-lapse incubators. There are differences among systems. Some use individual chambers, while others use a single incubation chamber. It’s important to evaluate how independently each chamber operates to help determine management of patient cultures and the equipment’s reliability.

Questions to ask:

  • Does each patient have a dedicated chamber?
  • Are the temperature and gas controls independent for each chamber?
  • Can a fault in one chamber impact the others?

2. Does Every Chamber Have A Dedicated Camera?

The imaging architecture is what allows embryo monitoring during culture. Some systems construct a dedicated camera for each chamber while others construct a shared imaging mechanism. It’s good to understand these differences to appreciate how images are obtained, as well as what happens if a component of the imaging mechanism requires servicing.

Questions to ask:

  • Is there a dedicated camera for every chamber?
  • How often are images obtained?
  • What happens if one of the cameras fails?

3. How Sensitive Is the Environmental Monitoring System?

Maintaining appropriate culture conditions requires constant monitoring of temperature and levels of gases and other reagents. It is important to know the parameters that embryologists monitor, as well as how deviations in those parameters are recognized and signaled. If the system alarms and warns the user of conditions that may require attention, the embryology team can better respond to those conditions and perhaps avoid losing an embryo.

Questions to Ask:

  • What parameters are monitored and what is the sensitivity of the sensors?
  • Are thresholds configurable?
  • What sort of deviations are signaled and how are they logged?

4. Does the Incubator provide active humidification?

Humidity management is a key specification when looking at an embryo incubator. Different systems will have different approaches to humidity control. Knowing how the humidity is managed can help the embryologist to compare the different system designs and work out what their lab’s requirements are.

Questions to ask:

  • Does the incubator have active humidification?
  • How is humidity kept in the chamber?
  • How is humidity monitored and controlled?

5. What is the recovery time for the incubator parameters?

The environmental conditions of an incubation chamber can temporarily fluctuate upon opening. Recovery time indicates the time taken by the incubator chambers to restore parameters such as temperature and gas levels to their specified ranges after the chamber is opened. Since the primary purpose of any incubator is to provide the optimal physiological parameters, its essential to compare the recovery times.

Questions to ask:

  • What is the recovery time for temperature and gas conditions after the lid is opened?
  • Under what conditions are recovery times measured and documented?
  • Can product evaluations show recovery performance effectively?

6. How Much Developmental Information Does the Imaging System Capture?

Image quality is not just about the resolution. The information for reviewing embryo development that will be captured depends upon the number of focal planes, frequency of image acquisition, and illumination method. Understanding these specifications can help you to compare imaging systems.

Questions to ask:

  • What is the number of focal planes that the system captures?
  • What is the light exposure to per embryo/per day?
  • Can images be assessed at different developmental stages?

7. Is there software with the incubator to provide detailed reports and remote access?

Software allows embryologists to easily retrieve, review and document developmental information. In general, consider software features that help with retrospective analysis, tracking patient records, and reporting. Remote access may be advantageous as long as data security and user permissions are implemented.

Questions to ask:

  • Does the software provide detailed reports including developmental-stage images?
  • Is it possible to review patient records and incubator settings remotely?
  • Can patient reports, embryo images/videos be exported?

8. Does a fault in one chamber affect the other chambers?

A reliable equipment not only prevents faults but also limits their operational impact. The chambers of an incubator should be designed in such a way that they are independent, and a problem in one chamber is isolated from others. In this way, it can be addressed separately without taking the entire incubator out of service. Additionally, one should always have a clarity on how chamber repair or replacement will be conducted.

Questions to ask:

  • Can a fault in one chamber affect the others?
  • Is it possible to repair or replace a faulty chamber separately?
  • Does servicing one chamber impact the others?

9. Who will Install, Service and Repair the equipment?

Post-sale support should also be a factor to consider when buying customized laboratory equipment. Servicing can be delayed due to travel time and scheduling when an overseas engineer from Principle Company of the product is required for each service call. Verify if local service engineers are available, if they have manufacturer-specific training and what will be the expected response time if any technical issues arise.

Questions to ask:

  • Are service engineers in India being trained by the principal company?
  • Can installation, maintenance and repairs be completed locally?
  • What is the expected response time?

Asking the right questions is the initial and most essential step towards making an informed decision for your IVF laboratory. To know if a system aligns with your laboratory needs, learn about the specifications, get a hands-on demonstration and understand the service support available prior to selecting a system.